WEFTEC 2026 See AccuDose live at the world's largest water quality and wastewater event Visit our booth
Volumetric Flow - AccuDose
Home AccuDose 2.0 Volumetric Flow
PLATFORM UPDATE · AUGUST 2026 Not an AI feature AccuDose Platform · Update 01

Know the flow.

Accurate flow measurement — without the flow meter.

Volumetric Flow is a calculation, not an AI feature. It uses the wet well drawdown method — combining your existing level sensor and pump state data with configured wet well dimensions — to deliver live GPM plus DMR-ready daily and monthly gallonage. No new hardware. No flow meter required.

Call us today: 866-310-1055
💧 Enable Volumetric Flow Calculation
Uses wet well drawdown method to calculate GPM, daily & monthly gallonage
SHAPE
Circle
Rectangle
DIAMETER (FT)
12
Area: 113.1 sq ft
✓ Volumetric Flow Calculation Ready
  • Wet Well level sensor (Analog Input → Wet Well Tank)
  • Pump state (Digital Input → Wetwell Pump State)
  • Wet well dimensions configured
Wet well area: 113.1 sq ft · Today: 0 gal · This month: 0 gal
VOLUMETRIC FLOW
LAST GPM
497.7
TODAY
25.1kgal
MONTHLY
25.1kgal
Pumps idle — level rising from inflow

Flow data without the meter.

Most lift stations don’t have a flow meter. Adding one means breaking the forcemain, installing a magmeter, and signing a five-figure check. Volumetric Flow gives you the same data from telemetry you’re already collecting.

Live GPM

Real-time gallons per minute, calculated every pump cycle. The same accuracy you’d get from a magmeter — without the magmeter.

Daily & monthly totals

DMR-ready flow summaries, calculated automatically. Drop them straight into your monthly NPDES Discharge Monitoring Report.

No extra hardware

Works on your existing AccuDose-equipped lift station. If you have a level sensor and pump state monitoring, you have everything Volumetric Flow needs.

Flow data, finally

Most lift stations have never had flow data. With Volumetric Flow, every site in your fleet becomes a flow-monitored site overnight.

How It Works

The wet well drawdown method — automated.

It’s the same calculation engineering teams have used for decades to verify pump performance — now running continuously on every station in your fleet.

01

Measure the drop

When a pump fires, the platform measures how fast the wet well level drops over a known interval.

02

Apply the geometry

You configure the wet well shape (circle or rectangle) and dimensions. The platform calculates volume per inch of drawdown.

03

Calculate live GPM

Volume drained ÷ pump runtime = gallons per minute. Every pump cycle adds a new data point.

04

Aggregate & report

Pump cycles aggregated into daily and monthly totals, ready for compliance reports and capacity planning.

See it in Action

Every lift station, finally a flow-monitored site.

Volumetric Flow launches August 2026 as part of AccuDose 2.0. Existing customers won’t pay extra — no upgrade fee, no separate subscription, no additional hardware.