AccuDose platform · Update 01

Know the
flow.

Flow measurement without the flow meter. Live GPM plus DMR-ready daily and monthly gallons, from the level sensor and pump state you already have.

Volumetric Flow is a calculation, not an AI feature. It uses the wet well drawdown method: your existing level sensor and pump state data, plus the wet well dimensions you enter once. No new hardware. No flow meter.

No flow meterLive GPMDaily and monthly totalsDMR-ready
0New hardware
GPMRecalculated every pump cycle
DailyAnd monthly gallons
1Setup step: wet well shape and size
Volumetric flowExample station
Wet well shapeCircle
Diameter12 ft
Wet well area113.1 sq ft
InputsLevel sensor · Pump state
Volumetric flow ready. No flow meter installed.
Last GPM497.7
Today25.1kgal
This month612kgal
Pumps idle. Level rising from inflow.
What it does

Flow data
without the meter.

Most lift stations have no flow meter. Adding one means breaking the forcemain, installing a magmeter and signing a five-figure check. Volumetric Flow gives you flow data from the telemetry you already collect.

01

Live GPM

Gallons per minute, recalculated on every pump cycle. The same drawdown math engineers use to verify pump performance, running all day on every station.

02

Daily and monthly totals

DMR-ready flow summaries, totaled automatically. Drop them straight into your monthly NPDES Discharge Monitoring Report.

03

No extra hardware

Works on any AccuDose-equipped lift station. If you have a level sensor and pump state monitoring, you have everything it needs.

04

Flow data, finally

Most lift stations have never had flow data. With Volumetric Flow, every site in the fleet becomes a flow-monitored site overnight.

How it works

The drawdown method,
automated.

The same calculation engineering teams have used for decades, now running continuously on every station.

  1. 01Measure the dropWhen a pump fires, the platform measures how fast the wet well level drops over a known interval.
  2. 02Apply the geometryYou enter the wet well shape, circle or rectangle, and its dimensions. The platform works out the volume per inch of drawdown.
  3. 03Calculate live GPMVolume drained divided by pump runtime is gallons per minute. Every pump cycle adds a new data point.
  4. 04Total and reportPump cycles roll up into daily and monthly totals, ready for compliance reports and capacity planning.

Every lift station,
a flow-monitored site.

Volumetric Flow is part of AccuDose 2.0. Existing customers do not pay extra. No upgrade fee, no separate subscription, no new hardware.